Send Message
Nanjing Suntay Steel Co.,Ltd 86-138-55514957 steelwiregroup@gmail.com
Single Acs Wire Lightning Protection For Opgw Optical Fiber Composite Overhead Gro

Single Acs Wire Lightning Protection For Opgw Optical Fiber Composite Overhead Gro

  • High Light

    aluminum stranded conductor

    ,

    aluminum clad steel wire

  • Product Name
    Aluminum Clad Steel Wire
  • Material
    Steel Wire And Aluminum
  • Application
    Opgw Optical Fiber Composite Overhead Ground Cable
  • Different Grades
    14% To 40% Iacs Conductivity
  • Place of Origin
    Anhui,China
  • Brand Name
    Global
  • Certification
    ISO9001-2008
  • Model Number
    3.0mm
  • Minimum Order Quantity
    5tons
  • Price
    discuss
  • Packaging Details
    standard export packing
  • Supply Ability
    200tons/day

Single Acs Wire Lightning Protection For Opgw Optical Fiber Composite Overhead Gro

 

 

Product description:

Aluminum clad steel wire is a piece of round wire made of a round steel core clad with a uniform and continuous aluminum layer. By structure ratio of steel and aluminum, aluminum clad steel wire has different grades, LB14, LB20, LB23, LB27, LB30, LB35 and LB40, with corresponding electric conductivities of 14%, 20.3%, 23%, 27%, 30%, 35% and 40% IACS (IACS stands for International Annealed Copper Standard). Featured by high strength, corrosion resistance and high conductivity, etc., aluminum clad steel wire is widely used in coastal areas, volcano areas, salt atmosphere areas and overhead power line used in areas seriously polluted by industrial materials containing SO2, NO and CO2, etc. It's the optimum material for transmission conductor with kilometric span and carrier cable for electrified railways.

Application:
Composition of Al Clad Strand Wires (ACS), Aluminum Conductors, Al Clad Steel Reinforced (ACSR/AW), OCGW,etc.

Standard:
ASTM B 415-92, ASTM B 502-93, AS 1222, IEC61232, JCS389

 

Approximate Properties of Hard-drawn 20.3% Conductivity Aluminum-Clad steel
Wire (20.3%)
 
 
 

Nominal Dia

Size


Calculated cross

sectional area


Min tensile
strength

Calculated
breaking
load

Mincoating
thickness

D.C resistance
at 20ºC≤


Weight
 
 
 
 
in. mm AWG mm2 cmils Mpa psi kn mm Ω/1000ft Ω/km kg/km 1b/1000ft  
0.2043 5.189 4 21.150 41740 1070 155000 22.60 0.259 1.222 4.009 139.32 93.63  
0.1880 4.775 4 17.908 35342 1100 160000 19.70 0.239 1.443 4.735 118.01 79.31  
0.1819 4.620 5 16.767 33090 1140 165000 18.10 0.231 1.541 5.056 110.48 74.25  
0.1729 4.392 5 15.150 29899 1170 170000 17.73 0.220 1.706 5.597 99.84 67.10  
0.1620 4.115 6 13.296 26240 1210 175000 16.00 0.206 1.943 6.375 87.61 58.88  
0.1549 3.934 6 12.155 23989 1240 180000 15.07 0.197 2.126 6.976 80.10 53.83  
0.1443 3,665 7 10.549 20820 1280 185000 13.50 0.183 2.450 8.038 69.47 46.69  
0.1369 3.477 7 9.495 18739 1310 190000 12.44 0.174 2.722 8.931 62.57 42.05  
0.1285 3.264 8 8.366 16510 1340 195000 11.20 0.163 3.089 10.135 55.15 37.03  
0.1144 2.906 9 6.633 13090 1340 195000 8.92 0.145 3.896 12.783 43.70 29.37  
0.1019 2.588 10 5.260 10380 1340 195000 7.07 0.129 4.912 16.116 34.66 23.29  
0.0907 2.304 11 4.170 8230 1340 195000 5.61 0.115 6.194 20.323 27.48 18.47  
0.0808 2.052 12 3.309 6530 1340 195000 4.45 0.103 7.811 25.628      

Single Acs Wire Lightning Protection For Opgw Optical Fiber Composite Overhead Gro 0