Send Message
Nanjing Suntay Steel Co.,Ltd 86-138-55514957 steelwiregroup@gmail.com
LRPC Steel Wire Strand For Railway Sleeper Production As Per ASTM A 416 , BS , DIN

LRPC Steel Wire Strand For Railway Sleeper Production As Per ASTM A 416 , BS , DIN

  • High Light

    prestressing steel 7 wire strands

    ,

    stranded steel wire

  • Material
    High Carbon Wire Rod 82B
  • Structure
    1x7
  • Size
    12.5mm,12.7mm,15.2mm,15.24mm,15.7mm
  • Standard
    ASTM,DIN,BS JIS G
  • Grade
    1860MPA
  • Packing
    2.5-3.2tons/coil On 2 Pallets
  • Loading Capacity
    25tons/20"
  • Place of Origin
    Anhui,China
  • Brand Name
    Litong Global
  • Certification
    ISO9001-2008
  • Model Number
    LT-181025
  • Minimum Order Quantity
    25tons
  • Price
    discuss
  • Packaging Details
    standard export packing in coil on 2 pallets
  • Supply Ability
    800tons/day

LRPC Steel Wire Strand For Railway Sleeper Production As Per ASTM A 416 , BS , DIN

 
1/2" LRPC Steel Wire Strand For Railway Sleeper Production As Per ASTM A 416 , BS , DIN
 
1*7 Wires Low Relaxation PC Strand
Description:
High tensile low relaxation steel strand for prestressed concrete
Specification:
Raw Material: High carbon steel wire rod SWRH 82B
Sizes:  12.5, 12.7, 12.9, 15.2, 15.24,15.7mm
Standards: ASTM A416-2006, ASTM A910-2005, ABNT NBR 7483:2008, AS 1311(Australia), AS/NZS 4672.1, BS5896-1980, EN10138-3, GB/T5224-2003, IS6006-1983, JISG3536, KSD7002, UNE36094-97 (Spain), NEN3868
Categories: plain, spiral ribs, indented, galvanized, PE coated, epoxy resin coated.
Tensile Strength over 1860MPa, Yield Strength over 1670MPa
Initial load to 70% breaking load, the relaxation at 1000 hours less than 2.0%
Lo over 610mm, the elongation over 4.0%
Package: baling strip, inner PVC film, outer damp-proof paper-plastic compound packing cloth, wooden pallet pedestal.
Package Weight: 2.8-3.2tons per coil
7-Wire Uncoated Steel Strand for Prestressed Concrete as per ASTM A 416

Min.Breaking Strength

Nominal
Dia.

Dia.
Tolerance

Norminal
Steel
Area

Nominal Weight

Min.
Breaking Load

Min.Load
at 1%Extension

Min.Elongation
Lo≥610mm

0.7 G.U.T.S
1000hNorminal Relaxation

MPAmmmmMm2Kg/KmKNKN%%
18609.53

 
 
+0.66,-0.15

54.84432102.392.1

 
 
≥3.5

 
 
≤2.5

11.1174.19582137.9124.1
12.7098.7775183.7165.3
15.24140.01102260.7234.6
17.80190.01492353.0318.0
200012.70+0.66,-0.1598.7775197.4177.7≥3.5≤2.5
15.24140.01102280.0252.0

 
7-Wire Uncoated Steel Strand for Prestressed Concrete as per GB/T5224

Min.Breaking Strength

Nominal
Dia.

Dia.
Tolerance

Norminal
Steel
Area

Nominal Weight

Min.
Breaking Load

Min.Load
at 1%Extension

Min.Elongation
Lo≥610mm

0.7 G.U.T.S
1000hNorminal Relaxation

MPAmmmmMm2Kg/KmKNKN%%
18609.50+0.30,-0.1554.843210286.6

 
 
≥3.5

 
 
≤2.5

 11.1074.2580138117
 12.70

 
 
+0.40,-0.20

98.7775184156
 15.201401101259220
 15.701501178279251
 17.801911500353318
196012.70+0.40,-0.2098.7775193174≥3.5≤2.5
 15.201401101274247

 
Welcome to enquiry our Products.
 
Attn:Ms Nancy
 
E-mail:greatsteelwirecable@yahoo.com
 
Tel:86-555-6757570
 
Mobile/what'sapp:86-13855514957
 
Skype:nancylsl